VXL 5-50A
line
 
Frequency
MHz
Attenuation
dB /100 ft
Attenuation
dB/100 m
Average Power, kW  
         
0.5 0.027 0.089 90.0
1 0.038 0.126 68.5
1.5 0.047 0.154 55.9
2 0.054 0.178 48.4
10 0.122 0.402 21.5
20 0.174 0.571 15.1
30 0.214 0.702 12.3
50 0.278 0.911 9.47
88 0.372 1.22 7.07
100 0.397 1.30 6.62
108 0.413 1.36 6.36
150 0.491 1.61 5.36
174 0.530 1.74 4.96
200 0.571 1.87 4.61
300 0.707 2.32 3.72
400 0.825 2.71 3.19
450 0.878 2.88 2.99
500 0.930 3.05 2.83
512 0.942 3.09 2.79
600 1.03 3.37 2.56
700 1.12 3.66 2.36
800 1.20 3.94 2.19
824 1.22 4.01 2.16
894 1.28 4.19 2.06
960 1.33 4.36 1.98
1000 1.36 4.46 1.94
1250 1.54 5.05 1.71
1500 1.71 5.60 1.54
1700 1.83 6.01 1.44
1800 1.89 6.21 1.39
2000 2.01 6.59 1.31
2100 2.07 6.78 1.27
2200 2.12 6.97 1.24
2300 2.18 7.15 1.21
3000 2.54 8.35 1.04
3400 2.74 8.99 0.961
4000 3.02 9.90 0.873
4900 3.41 0.772 0.772
       
 
Description
 
Cable Ordering Information
Standard Cable
7/8"Standard Cable , Standard Jacket
fire Retardant Cables
7/8"Fire Retardant Jacket (CATVR)
Low VSWR and Specialized cables
7/8"Low VSWR ,specify operating band
Jumper Cable Assemblies

VXL5-50

VXL5RN-50

VXL5P-50-(**)

Characteristics
Electrical Impedance, ohms
Maximum Frequency, GHz
Velocity, percent
Peak Power Rating, Kw
Dc Resistance, ohms/1000ft(1000m)
Inner
Outer
Dc Breakdown, volts
Jacket Spark, volts
Capacitance, Pf/ ft(m)
Inductance, Ph/ ft(m)

50 +- 1
4.9
88
90
0.82(2.70)
0.36(1.19)
6000
8000
22.6(74.2)
0.06(0.197)

 
Mechanical
 
Outer conductor
Inner Conductor
Diameter over Jacket, in (mm)
Diameter over Copper outer Conductor, in(mm) Diameter Inner Conductor, in (mm)
Minimum Bending Radius, in(mm)
Number of Bends, minimum (typical) Bending Moment, lb-ft (N.m)
Cable Weight, lb/ft(kg/m)
Tesile strength, lb(kg)
Flat Plate Crush Strength, lb/in(kg/mm)
Copper
Copper Tube
1.08(27.5)
0.98(24.9)
0.371(9.42)
5(125)
15(40)
12(16.3)
0.29(0.43)
225(102)
80(1.4)
 
 



  top

Standard conditions: For attenuation. VSWR 1.0, ambient temperature 20’C (68’F) For Average power. VSWR 1.0 ambient temperature 40’C (104’F) Inner conductor temperature 100’C(212’F), no solar loading
     
Cables : RF Coaxial & Microwaves Cables : Heliax Cable : LDF 1-50 Cable: LDF 2-50 Cable : LDF 4-50 Cable:
LDF 4-5.50 Cable: LDF 5-50A Cable: VXL 5-50A Cable : FSJ Series Cables: FSJ 1-50A Cable: FSJ 2-50A Cable: FSJ 4-50B Cable:
     


    Home  |  About Us  |  Products  |  Contact Us   |  E-mail  |  Sitemap  |  Links